Zyxel GS1900: Patch 2 fails to stop exploit, Patch 3 is needed
Key takeaways
- Switches on 2.90 Patch 2 or earlier firmware need 2.90 Patch 3 for their model
- The exploit needs no login and runs commands as root, with Binarly rating it 9.8 out of 10
- Zyxel lists no workaround, so management interfaces should be taken off untrusted networks until updated
- 564 of the 996 switches attacked used factory-default credentials
Zyxel's June fix for its GS1900 network switches does not stop the exploit attackers have been using, according to researchers at Binarly. The vendor has now released 2.90 Patch 3 firmware for 10 GS1900 models to close the underlying flaw, tracked as CVE-2026-107441. The flaw lets an attacker who can reach a switch's web management interface run commands without logging in. This is a firmware assessment for the people who run these switches.
What the new firmware does well
Patch 3 fixes the actual root cause rather than a symptom. Binarly traces the flaw to dispatcher.cgi, the program that handles web requests on the switch. It copies each request parameter into a fixed area sized for 140 parameters. It never checked how large a single parameter was, and before Patch 2 it did not check how many parameters it had stored either.
The exploit sends an oversized 140th parameter. That overruns the end of the area and overwrites the parameter counter. The next parameter is then written outside the area, which lets the attacker swap the function the program is about to call for one that runs their command, with root privileges.
In Patch 3, the counter is checked before a parameter is copied, and the copy is limited in size. Binarly says this fixes the flaw. Patch 3 was posted on 23 October.
Where it falls short
The bigger problem is the history. Patch 2, released after a 16 June advisory for CVE-2026-7273, added a check on the counter. But the check runs only after the oversized parameter has been copied. By then the counter holds the attacker's value, so the check does not block the write. Binarly says the exploit works against Patch 2 without changes, and that it tested on emulated firmware and real hardware. The exploit's own list of supported firmware includes the Patch 2 build for the GS1900-24.
Zyxel told the researchers that CVE-2026-7273 covered the missing counter check and that it treats the missing size check as a separate flaw. Binarly offers two readings: either Patch 2 was a faulty fix for CVE-2026-7273, or the attacks exploited a different flaw from the one CISA listed. Either way, attackers had a working exploit before a fix for the size check existed, which is why the researchers call it a zero-day.
Gaps remain in the vendor's guidance:
- The advisory lists no workaround for owners who cannot update yet.
- It does not say whether updating removes access an attacker may already have.
- It does not say what owners should check if a switch may have been compromised.
- It does not say whether the new flaw has been exploited.
The severity scoring also differs. Binarly rates the flaw 9.8 out of 10 on the CVSS scale, against 8.8 in the vendor's CVE entry. Binarly says an attacker "only needs network reachability to the management service", while Zyxel describes a "LAN-based, unauthenticated attacker". For a switch whose management page is reachable from anywhere beyond a locked-down management VLAN, that gap in wording matters.
How it compares
Rather than rival products, the useful comparison is between the three firmware states a GS1900 owner might be on.
| Firmware | Status | Exploit works? | Action |
|---|---|---|---|
| Earlier than 2.90 Patch 2 | Affected | Yes | Update to Patch 3 for your model |
| 2.90 Patch 2 (June fix for CVE-2026-7273) | Affected, per Binarly | Yes, without changes | Update to Patch 3 for your model |
| 2.90 Patch 3 (posted 23 October) | Fixes CVE-2026-107441 | Not reported to work | Verify the build matches your model |
The point for anyone tracking exposure is that a CVE listing is not the same as a fix. The US Cybersecurity and Infrastructure Security Agency (CISA) added CVE-2026-7273 to its Known Exploited Vulnerabilities (KEV) catalog on 21 September, with a federal deadline of 24 September to apply the Patch 2 firmware. The deadline required only the Patch 2 firmware, which Binarly says does not stop the exploit. Teams that drive patching from the KEV list alone will miss it; our guide on how to check the CISA KEV catalog covers that gap.
Pricing and value
The source gives no price for the firmware, and the advisory does not suggest a charge. The cost is operational: a firmware push across every GS1900 on the estate, plus a check of each unit for signs of compromise. GreyNoise reported on 21 September that attackers took data from 996 GS1900 switches around 17 August. The data included switch configurations, hashed root credentials and network information. Of those 996 switches, 564 still used factory-default credentials. The report does not say which firmware the switches ran or how attackers reached them, so the figures show the attackers' targeting, not the effect of Patch 2.
GreyNoise tied the activity to a group that is the same as, or related to, one Acronis tracks as Red Heron and describes as Chinese-speaking. Binarly found the exploit on 17 September in an open folder on a server that also acted as a command server for the JITTERLY backdoor.
Who should act
Anyone running a GS1900 on Patch 2 or earlier should treat the update as urgent. That includes any organisation that applied the Patch 2 firmware CISA required of federal agencies by 24 September. Binarly says it will soon publish a smaller proof-of-concept version of the exploit, so the window for quiet patching is narrowing.
What this means
- Update every GS1900 on Patch 2 or earlier to the Patch 3 build for its model.
- Take the web management interface off any network segment that untrusted users can reach, since Zyxel's advisory lists no workaround.
- Change factory-default credentials; more than half the attacked switches still used them.
- Treat configurations and root credential hashes on previously exposed switches as potentially taken, and rotate them, because Zyxel gives no guidance on whether updating removes existing access.
- Track CVE-2026-107441 separately; it is not in the KEV catalog.
Verdict
Any GS1900 on Patch 2 or earlier firmware needs the Patch 3 build for its model. Patch 2 does not stop the exploit, and Binarly says it will soon publish a smaller proof-of-concept version. Owners who cannot update this week should restrict management access first and treat any switch that was reachable and unpatched since August as a possible leak of configuration data. Watch for Zyxel guidance on post-compromise checks and for any sign that CISA adds CVE-2026-107441 to its catalog.
For similar cases of fixes arriving after active exploitation, see our coverage of the Cisco ISE zero-day and the FortiMail zero-day.
Frequently asked questions
Does Zyxel's 2.90 Patch 2 firmware protect GS1900 switches?
No. Binarly says the exploit works against Patch 2 without changes. Switches on Patch 2 or any earlier firmware need the 2.90 Patch 3 build for their model.
Do I need to be logged in to exploit the flaw?
No. The exploit lets anyone who can reach the switch's web management interface run commands without logging in, and the commands run with root privileges.